Published  |  Last updated

Quick Answer: Adaptive clinical trial designs allow prospectively planned changes, such as stopping early or adjusting the sample size, based on accumulating trial data, under rules written down before the trial starts.1 The FDA guidance of November 2019 asks for four things: control of the chance of erroneous conclusions, reliable effect estimates, a completely prespecified design and maintained trial integrity.1 The ICH E20 guideline is still a Step 2b draft on the EMA site as of 3 November 2026.2 A real case shows how this works: the SHINE stroke trial (1,151 patients, CC BY 4.0) crossed its futility bound at look 3 and stopped after look 4, while a prespecified Bayesian alternative replayed on the same data crossed its futility bound at 800 patients against 936.3 Editverse simulated the published bounds in R (seed 14940, 400,000 trials per scenario): 72.9% of no-effect trials stop early for futility, close to the 73% the authors report.3,4 This is one trial and one dataset, so read it as a worked example and not as a benchmark.

What Adaptive Clinical Trial Designs Are

The FDA defines an adaptive design as a clinical trial design that allows prospectively planned modifications to one or more aspects of the design based on accumulating data from subjects in the trial.1 Two words carry the definition. Prospectively means the adaptation is planned and its details are specified before any comparative analysis of accumulating data, and in nearly all cases it is described in the protocol and a separate statistical analysis plan before the trial begins.1 A fixed sample trial, by contrast, has a targeted total sample size or number of events set at the design stage and not subject to planned adaptation.1

An interim analysis, in the FDA wording, is any examination of data from subjects while the trial is ongoing, and it is comparative when treatment groups are identified, even with codes such as A and B.1 That distinction matters later, because adaptations based on non-comparative data have different error properties from adaptations based on comparative data.1

What adaptive designs can offer and what they cost

The FDA groups the potential advantages into four categories and describes limitations in a separate section.1

  • Statistical efficiency. Group sequential and sample size adaptive designs can give greater power than a comparable non-adaptive design, or the same power with a smaller expected sample size or shorter expected duration.1
  • Ethical considerations. Stopping early when a trial is unlikely to show effectiveness can reduce the number of patients exposed to an ineffective investigational treatment.1
  • Improved understanding of drug effects. Enrichment and dose selection designs can answer broader questions than a fixed design would allow at feasible sample sizes.1
  • Acceptability to stakeholders. An adaptive design may be considered more acceptable than a comparable non-adaptive design because of the added flexibility: sponsors might be more willing to commit to a trial that allows planned design modifications, and patients may be more willing to enroll in trials that use response-adaptive randomization.1
  • Limitations. Specific analysis methods are needed to avoid inflated error and biased estimates, the minimum and expected sample size may fall while the maximum rises, and logistics for limiting access to interim results add cost.1

Types of Adaptive Clinical Trial Designs

The table follows the FDA guidance and lists what each design can change and the main concern for each.1

DesignWhat can change at an interim lookMain statistical concern
Group sequentialThe trial stops early for efficacy or futility under prespecified criteria1Repeated tests inflate the type I error unless boundaries are set; estimates tend to be biased toward larger effects1
Sample size re-estimation, non-comparativeThe sample size is updated from pooled data using a nuisance parameter, such as the control event rate1Generally no or limited effect on the type I error probability1
Sample size re-estimation, comparativeThe sample size changes according to the interim estimate of the treatment effect1Changing the size without proper adjustment can inflate the type I error; the FDA notes it can more than double in a design with one interim analysis1
Adaptive enrichmentLater enrollment is restricted to a targeted subpopulation1Multiplicity across stages and across populations1
Treatment arm or dose selectionArms or doses are added or dropped; platform trials share a common control1Testing must account for selecting the best dose or arm1
Response-adaptive randomizationAllocation probabilities shift as outcome data accumulate1Generally no increase in type I error with appropriate analysis; the FDA calls the arguments for it controversial1
Endpoint selectionThe primary endpoint is chosen at an interim analysis by a prespecified rule1Testing must account for the adaptive choice; early discussion with the FDA review division is recommended1

Swipe sideways to see every column.

For a broader plain-language overview, see Adaptive Designs in Clinical Trials Explained.

Examples the FDA cites

The guidance illustrates the designs with named trials, each described there as follows.1

  • Eliprodil, head injury. An interim analysis on pooled non-comparative data led to a sample size increase from 400 to 450 patients.1
  • PARADIGM-HF, heart failure. Three planned interim analyses with efficacy stopping rules reduced the expected sample size and duration; the trial stopped after the third interim analysis because the superiority boundary had been crossed.1
  • Nine-valent HPV vaccine. An interim analysis selected one of three dose formulations to carry into the second stage.1
  • STAMPEDE, prostate cancer. Multiple interim analyses could drop arms that performed poorly, with a common control group.1
  • PREVAIL II, Ebola virus disease. A Bayesian adaptive design with interim analyses planned after every 2 patients completed and no action before 12 per group were enrolled.1

Each bullet reflects the FDA description, not a re-reading of the original trial papers.1

Dose-finding, randomization and Bayesian designs

The continual reassessment method is an approach to adaptively escalate doses in early-phase trials based on observed toxicities, to estimate the maximum tolerated dose.1 The FDA also warns that rules allowing quickly escalating doses could expose subjects to unsafe doses, so the speed of escalation belongs in the design choice.1 For allocation, covariate-adaptive methods such as minimization promote balance on baseline characteristics, while response-adaptive randomization shifts allocation as outcomes accumulate and works best when outcomes are known quickly.1 Bayesian adaptive designs are a wide family: predictive modelling to govern interim decisions, assumed dose-response relationships, borrowing from external sources and posterior probabilities as success criteria. The same principles apply as for other adaptive designs, and simulation is often needed to estimate their operating characteristics.1

What the FDA, EMA and ICH Expect From an Adaptive Trial

Three regulatory documents and one reporting guideline shape practice. Each row of the table is limited to what the cited document says.

DocumentStatus and scopeWhat it asks of a sponsor
FDA guidance, November 2019Nonbinding recommendations for adaptive designs in trials of drugs and biologics1Control the chance of erroneous conclusions, estimate effects reliably, prespecify the design completely, keep trial integrity1
EMA reflection paper, 2007CHMP/EWP/2459/02 on confirmatory trials planned with an adaptive design, adopted 18 October 20075Describe and justify the interim analysis and planned modification in the protocol; unplanned adaptations make a confirmatory trial exploratory5
ICH E20, Step 2b draftDraft listed on the EMA site as of 3 November 2026; consultation ran 30 June to 30 November 20252Confirmatory trials planned with an adaptive design, with pre-specified modifications based on interim analysis; discusses Bayesian methodology2
ACE reporting extension, 2020Extension of CONSORT 2010 for randomised trials that use an adaptive design6Report the adaptations, decision criteria, interim results and methods so the trial can be interpreted and reproduced6

Swipe sideways to see every column.

The FDA organises its guidance around four principles for trials meant to provide substantial evidence of effectiveness: the chance of erroneous conclusions should be adequately controlled, estimation of treatment effects should be sufficiently reliable, details of the design should be completely prespecified, and trial integrity should be appropriately maintained.1 The EMA reflection paper adds that using an adaptive design implies that the methods control the prespecified type I error, give correct estimates and confidence intervals, and plan an assessment of homogeneity of results from different stages.5 It also states that adaptive designs should not be seen as a means to alleviate the burden of rigorous planning.5

A Real Case: The SHINE Trial Under Two Adaptive Designs

The Stroke Hyperglycemia Insulin Network Effort (SHINE) trial compared intensive glucose control with standard of care in patients with hyperglycemia and stroke. The primary outcome was a favourable neurologic outcome at 90 days. The maximum sample size was 1,400 patients, giving 80% power to detect a rise from 25% on standard care to 32% on intensive control with a two-sided test at the 5% level.3 Broglio and colleagues published an open-access comparison (CC BY 4.0) of the frequentist design that was run with a Bayesian alternative specified in advance, using the actual patient-level data.3

How the implemented SHINE design worked

SHINE used a group sequential design with two-sided efficacy and futility boundaries and response-adaptive randomization. The boundaries came from the Gamma family spending functions and closely resembled an O’Brien-Fleming boundary. Futility boundaries were non-binding. Interim analyses were planned when 500, 700, 900 and 1,100 consecutive patients had reached 90-day follow-up, with multiple imputation for missing outcomes, and a blinded sample size re-estimation was planned before the first look.3 The re-estimation did not raise the sample size.3

What the four looks showed

The table reproduces the published bounds and results and adds one column computed by Editverse: the z value implied by each printed adjusted p-value.3

LookEnrolled / analysedEfficacy bound (z, p)Futility bound (z, p)Adjusted risk differenceReported pz from p (Editverse)Decision
13579 / 50032.97, .00330.06, .9532.8%3.1331.514Continue3
23771 / 70032.86, .00430.13, .9030.9%3.5630.584Continue3
33936 / 90032.65, .00830.45, .6530.1%3.9630.054Futility bound crossed; board did not stop3
431137 / 110032.42, .0231.05, .293−0.1%3.9230.104Futility bound crossed; board recommended stopping3

Swipe sideways to see every column.

Editverse checked the table in R. Converting each bound z to a two-sided p-value gives the printed p-values (for example 2.97 gives 0.003 and 1.05 gives 0.29), and converting the printed adjusted p-values back gives z of 1.51, 0.58, 0.05 and 0.10. Looks 1 and 2 sit between the bounds and looks 3 and 4 fall below the futility bound, which matches the decisions the authors describe. Because the p-values are printed to two decimals, the decisions were also checked across the rounding range and none changes.3,4

Chart of the four SHINE interim analyses: absolute z values 1.51 at 500 patients analysed and 0.58 at 700 sat between the futility and efficacy bounds, and 0.05 at 900 and 0.10 at 1100 fell inside the futility zone
SHINE interim results against stopping bounds. Redrawn in R from Broglio et al., CC BY 4.0; z recovered from printed p-values by Editverse.

The trial crossed its futility boundary at the third look, with 936 patients randomized and 900 patients with 90-day follow-up, and the adjusted effect favoured intensive control by 0.1%. The data safety and monitoring board did not recommend stopping, and the trial continued. The boundary was crossed again at the fourth look, with 1,137 randomized, and the board recommended stopping for futility. The final total was 1,151 patients: 123 of 570 (21.6%) favourable in the control arm and 119 of 581 (20.5%) in the treatment arm.3 Editverse computed the unadjusted risk difference from those counts as -1.1 percentage points (95% CI -5.8 to 3.6).3,4

What the Bayesian replay showed

The alternative design was fully Bayesian, a Goldilocks sample size design with the same primary endpoint, sample size, type I error and power. It looked after 500 patients and then after every additional 100, and used 6-week outcomes through a longitudinal model to inform patients not yet at 90 days. It stopped for success if the predictive probability of success at the current sample exceeded 99%, and for futility if the predictive probability of success at 1,400 patients fell below 5%.3

EnrolledWith 90-day outcomeFavourable, treatment armFavourable, control armPredictive probability of success, current samplePredictive probability of success, 1,400
4983432326.6%324.6%3below 1%321.1%3
5793515325.7%322.3%3below 1%339.7%3
7003621325.1%323.4%3below 1%315.6%3
8003715323.1%322.8%3below 1%32.0%, below the 5% futility threshold3

Swipe sideways to see every column.

At the fourth look, with 800 patients randomized and 715 with 90-day outcomes, the predictive probability of success at the maximum sample size was 2.0%, below the 5% threshold, so the alternative design crossed its futility boundary 136 patients, or 14.5%, earlier than the 936 at which SHINE first crossed its own. Against the 1,151 SHINE finally enrolled, 800 is 351 fewer patients, a 30.5% difference, and 57.1% of the 1,400 maximum (all three shares computed by Editverse). The authors write that the difference is driven by the enrollment rate and by the implemented SHINE design needing to wait until patients reached the 90-day follow-up.3 The Bayesian design itself looked after 500 patients and then after every additional 100, which is a design fact and not the cause the authors name.3

Bar chart of patients enrolled when the stopping rule fired: planned maximum 1,400, SHINE total enrolled 1,151, SHINE first futility crossing 936 and the replayed Bayesian design 800
Patients enrolled at the stop. Redrawn in R from Broglio et al., CC BY 4.0; shares of 1,400 computed by Editverse.

Editverse recomputation of the SHINE design

Editverse simulated the published four-look design in R. The inputs were the efficacy bounds 2.97, 2.86, 2.65 and 2.42, the futility bounds 0.06, 0.13, 0.45 and 1.05, looks at 500, 700, 900 and 1,100 of 1,400 patients, a final critical value of 2.02 (rounded; the exact calibration is 2.023), and two scenarios: no effect, and 25% against 32% favourable outcomes. Each scenario used 400,000 simulated trials, with seed 14940 for no effect and 14941 for the 25% against 32% scenario.4

  • No effect: 72.9% of trials stopped early for futility, 2.0% stopped early for efficacy and 25.1% reached the final analysis. The authors report a 73% probability of early futility under the null.3,4
  • 25% against 32%: 80.8% of trials ended with a positive result, against the 80% power the authors state; 7.9% stopped early for futility.3,4
  • Expected sample size: about 1,053 with no effect and 1,040 in the 25% against 32% scenario, against a 1,400 maximum; the authors report an expected size of 1,039 under the null, so this simulation is close but not identical.3,4
Bar chart of simulated SHINE stopping outcomes: with no treatment effect 72.9 percent of trials stop early for futility, 2.0 percent for efficacy and 25.1 percent reach the final analysis; with a 25 percent versus 32 percent effect 7.9, 58.1 and 34.0 percent
Simulated stopping outcomes under the published SHINE bounds. Computed in R by Editverse, seed 14940 and 14941, 400,000 trials per scenario.

The match depends on two readings that Editverse inferred and that the paper does not state in these words. The 73% figure reproduces when the futility rule is read as stopping once the absolute z falls below the printed futility bound (a two-sided, inner futility region), and the final critical value was calibrated so that the four printed efficacy bounds give a two-sided type I error of 5%: the exact value is 2.023, and the rounded 2.02 used in the simulation gives 5.03%. The simulation ignores response-adaptive randomization, delayed outcome follow-up and the board review, so it checks the stopping rules and not the whole trial.3,4 The unadjusted comparisons in the paper reproduce exactly from the printed counts: 102 of 483 against 102 of 453 gives a difference of -1.4 (-6.7 to 3.9) and 89 of 408 against 89 of 392 gives -0.9 (-6.7 to 4.9), matching the printed values.3,4

What the case shows and what it does not

It shows that a prespecified group sequential design and a prespecified Bayesian design reached the same conclusion on the same patients, that the Bayesian version reached it earlier, and that a non-binding futility boundary can be crossed without the trial stopping at once. The authors write that the difference is driven by the enrollment rate and by the implemented SHINE design needing to wait until patients reached the 90-day follow-up.3 It does not show that a Bayesian design is better in general, because the replay used the real treatment assignments, did not include response-adaptive randomization, and could not reproduce the board decision. The paper also notes that more frequent looks raise the chance of an incorrect early stop and add operational burden.3

Error Control and Expected Sample Size

The FDA gives a simple example of why control matters. If a group sequential trial tests at 50% and at 100% of the planned subjects, each at the conventional one-sided 0.025 level, the overall chance of a type I error exceeds 2.5%.1 Editverse computed the exact figure in R as 4.2%, using the correlation of the two test statistics, so the interim test must use a stricter boundary.4

The FDA also states that a design with one interim analysis at half the information and an O’Brien-Fleming boundary reduces the expected sample size by roughly 15% if the alternative with 90% power is true, relative to a single analysis at the end.1 Editverse recomputed this with the gsDesign classic O’Brien-Fleming bounds of 2.797 and 1.977 (one-sided 0.025, 90% power) and compared the expected sample size with a fixed design of the same power, which gave 14.9%; the Lan-DeMets spending-function version gives 12.3%. The figure therefore depends on the boundary variant, and the FDA statement is a rounded illustration.4

Keeping the Trial Intact: Access to Interim Results

The FDA strongly recommends that access to comparative interim results be limited to individuals with relevant expertise who are independent of those conducting or managing the trial.1 Two reasons are given: it gives the greatest confidence that unplanned changes were not driven by accumulating data, and it protects accrual, adherence, retention and endpoint assessment.1 The adaptation can be handled by a dedicated independent body or by the data monitoring committee, the latter being best reserved for group sequential and other simple designs. The guidance suggests confidentiality agreements, firewalls and a data access plan, and notes that a sample size increase can itself let observers back-calculate the interim effect.1

What to Document Before You Start

For a trial that will support a regulatory application, the FDA lists the documentation expected before the trial begins. Use it as a planning checklist.1

  1. 1State the rationale for the design. Compare its operating characteristics with alternative adaptive and non-adaptive designs; the final choice is the sponsor responsibility.1
  2. 2Describe the adaptation plan. Give the number and timing of interim analyses, which aspects may change and the rule that decides.1
  3. 3Name the roles and the data access plan. Say who analyses interim data, who sees the results, how decisions are made and what is shared.1
  4. 4Prespecify the statistics. Interim methods, hypothesis tests, effect estimates, uncertainty and the software to be used.1
  5. 5Report operating characteristics. Type I error, power, expected, minimum and maximum sample size, bias and confidence interval coverage.1
  6. 6Provide the simulation report with code and seeds. Where simulation is the main tool, include example trials, scenarios, the number of iterations and the code with random seeds; the FDA gives 100,000 iterations as an example that bounds a type I error estimate to about plus or minus 0.1%.1

Reporting an Adaptive Trial With the ACE Extension

The ACE statement extends CONSORT 2010 for randomised trials that use an adaptive design. Its main-report checklist has seven new items, nine modified items, six unchanged items with added explanatory text and 20 unchanged items, and the abstract checklist asks for the word adaptive in the content or at least as a keyword.6 The seven new items are 3b, 11c, 12b, 14c, 15b, 17c and 24b: type of adaptive design, confidentiality of interim information, methods for the implemented adaptations, adaptation decisions made, similarity of the population between stages, interim results used, and where the statistical analysis plan can be found.6 The table maps four items to the SHINE paper, to show what each looks like in practice.

ACE itemWhat it asks you to reportWhere SHINE reports it (mapped by Editverse)
3b6Type of adaptive design, with the prespecified adaptations and the statistical information behind them6Methods: group sequential design with two-sided efficacy and futility boundaries, response-adaptive randomization and a blinded sample size re-estimation before the first look3
7b6Interim decision criteria, whether binding or non-binding, and the planned and actual timing of looks6Methods: futility boundaries non-binding; looks planned at 500, 700, 900 and 1100 patients with 90-day follow-up3
14c6The adaptation decisions made in light of the criteria and the accrued data6Results: futility bound crossed at look 3 and the board did not recommend stopping; stopped after look 43
17c6The interim results used to inform the decisions6Table 1 of the paper: bounds, z values, risk differences and p-values at each look3

Swipe sideways to see every column.

Choosing Whether to Adapt

The FDA states that it does not intend to require or restrict adaptive designs, and encourages sponsors to explore a variety of designs and discuss them at meetings such as end-of-phase-2.1 Some practical readings follow from the guidance. When the main uncertainty is a nuisance parameter such as the control event rate or the variance, a non-comparative sample size adaptation is an attractive choice.1 When the true effect size is uncertain, comparative sample size adaptation can protect power but needs a method that controls the error rate.1 When a biologic rationale points to a subgroup, adaptive enrichment can be motivated, provided the rationale comes from earlier trials or strong biologic plausibility.1 When outcomes take longer to observe than enrollment takes, the value of adapting is limited.1

Need the Analysis Run or Checked? Consult Editverse

Editverse subject-matter experts work to COPE, ICMJE and GPP 2022 guidance, with institutional and country-specific ethics followed.

Editverse logo

Editverse

Methodology Consultation

Planning a study? Have the research design reviewed first.

You send: your research question, draft design and sampling plan.

You get: three 45-minute sessions with PhD methodologists, a research design review with recommendations, and a written methodology framework document.

When: At proposal stage, while the design can still change.

Methodology Consultation Package · $400

Strengthen my design →

Editverse logo

Editverse

Statistical Analysis

Need the analysis run in R, SPSS or STATA?

You send: your data, research questions and preferred software.

You get: annotated scripts or syntax, complete output files, an interpretation guide and publication-ready tables; standard turnaround is 4-6 business days.

When: Your data are collected and the results section is not.

SPSS/R/STATA Statistical Analysis · $400

Get my data analysed →

Editverse logo

Editverse

Manuscript Writing

Trial finished? Write it up for a journal.

You send: your data, outline and references.

You get: a manuscript written by PhD-qualified subject matter experts, with technical review, statistical review and a plagiarism check; the service page states ICMJE and COPE compliance.

When: Your project is finished and the paper is not.

Manuscript Writing Services · $1,500

Write my paper →

Free Research Tools from Editverse

Frequently Asked Questions

What are adaptive clinical trial designs?

The FDA defines an adaptive design as a clinical trial design that allows for prospectively planned modifications to one or more aspects of the design based on accumulating data from subjects in the trial. Prospective means the adaptation is planned and its details specified before any comparative analysis of accumulating data.

What types of adaptive design are there?

The FDA guidance describes group sequential designs, sample size adaptations, adaptive enrichment, adaptive treatment arm or dose selection, adaptive patient allocation such as response-adaptive randomization, adaptive endpoint selection, and designs that combine several of these. Each carries its own risks to error control, so each needs a prespecified rule.

Do adaptive designs need fewer patients?

Not always. The FDA notes that an adaptive design can have a smaller minimum and expected sample size but a larger maximum than a comparable non-adaptive design. In the SHINE stroke trial the group sequential design stopped for futility at 1151 patients against a planned maximum of 1400, and the replayed Bayesian alternative crossed its futility boundary at 800.

Does an adaptive design inflate the type I error rate?

It can. Testing twice at the usual one-sided 0.025 level, at half and at all of the planned subjects, gives an overall false positive probability of about 4.2 percent, which Editverse computed in R, so adaptive designs use stopping boundaries or other methods that control the overall error rate. Simple group sequential designs have well-established boundaries; complex designs often need simulation.

What do the FDA and EMA say about adaptive designs?

The FDA guidance of November 2019 sets four principles: control the chance of erroneous conclusions, estimate treatment effects reliably, prespecify the design completely, and maintain trial integrity. The EMA reflection paper of 2007 advises caution for confirmatory trials and says adaptations introduced without proper planning make the trial exploratory. The ICH E20 guideline is a Step 2b draft on the EMA site as of 3 November 2026.

What is the difference between blinded and unblinded sample size re-estimation?

Blinded or non-comparative re-estimation uses pooled outcome data without treatment assignment to update a nuisance parameter such as the control event rate or the variance, and generally has no or limited effect on the type I error probability. Re-estimation based on comparative interim results, which uses the estimated treatment effect, can inflate the error rate and needs a method that accounts for it.

How should an adaptive trial be reported?

Use the ACE extension of CONSORT, published in 2020. It adds seven new items, including the type of adaptive design and its prespecified adaptations, measures to keep interim information confidential, statistical methods for the implemented adaptations, the adaptation decisions made, the interim results used, and where the statistical analysis plan can be found.

Can a trial continue after it crosses a futility boundary?

That depends on whether the boundary is binding. The FDA explains that non-binding futility rules are guidelines and adding them does not raise the type I error probability, while with binding rules the error rate is controlled only if the trial stops. The SHINE futility boundary was non-binding, and the trial continued after the third look before stopping after the fourth.

References

  1. U.S. Food and Drug Administration, CDER and CBER. Adaptive Designs for Clinical Trials of Drugs and Biologics: Guidance for Industry. November 2019 (nonbinding recommendations; full PDF read 3 November 2026). www.fda.gov/media/78495/download
  2. European Medicines Agency. ICH E20 adaptive designs for clinical trials: scientific guideline page, listing the Step 2b draft (EMA/CHMP/ICH/206586/2025; consultation 30 June to 30 November 2025). Page read 3 November 2026. www.ema.europa.eu/en/ich-e20-adaptive-designs-clinical-trials-scientific-guideline
  3. Broglio K, Meurer WJ, Durkalski V, Pauls Q, Connor J, Berry D, Lewis RJ, Johnston KC, Barsan WG. Comparison of Bayesian vs Frequentist Adaptive Trial Design in the Stroke Hyperglycemia Insulin Network Effort Trial. JAMA Netw Open. 2022;5(5):e2211616. doi:10.1001/jamanetworkopen.2022.11616. Licence CC BY 4.0 (PMC9096598; licence read in the PMC XML on 3 November 2026). doi.org/10.1001/jamanetworkopen.2022.11616
  4. R Core Team. R 4.3.3. With the gsDesign package (version 3.11.0, CRAN) for group sequential boundaries and the mvtnorm package (version 1.3.7, CRAN) for multivariate normal probabilities. Used by Editverse on 3 November 2026. cran.r-project.org/package=gsDesign
  5. European Medicines Agency, CHMP. Reflection paper on methodological issues in confirmatory clinical trials planned with an adaptive design. CHMP/EWP/2459/02, adopted 18 October 2007 (full PDF read 3 November 2026). www.ema.europa.eu/en/documents/scientific-guideline/reflection-paper-methodological-issues-confirmatory-clinical-trials-planned-adaptive-design_en.pdf
  6. Dimairo M, Pallmann P, Wason J, Todd S, Jaki T, Julious SA, et al. The Adaptive designs CONSORT Extension (ACE) statement: a checklist with explanation and elaboration guideline for reporting randomised trials that use an adaptive design. BMJ. 2020;369:m115. doi:10.1136/bmj.m115. Licence CC BY 4.0 (PMC7298567). doi.org/10.1136/bmj.m115

Editverse Research Team | Updated November 2026