Free STARD Flow Diagram Generator for Diagnostic Accuracy Studies
Generate the official STARD 2015 flow diagram for your diagnostic test accuracy study. Live auto-calculation through enrolment, testing, and analysis. 300/600 dpi PNG and fully editable PowerPoint exports. No data leaves your browser.
This tool generates the STARD 2015 flow diagram — the current international standard for diagnostic accuracy reporting — from the counts you enter. It tracks the Enrolment, Testing (index test and reference standard), and Analysis stages, with auto-calculated totals at each step.
When to Use the STARD Flow Diagram
Use STARD 2015 whenever your study evaluates the diagnostic accuracy of a test, biomarker, imaging modality, clinical prediction rule, or screening instrument. STARD applies whether the index test is a laboratory assay, imaging finding, questionnaire, or AI algorithm. The 2015 update is the current version; STARD-AI, published in 2025 in Nature Medicine, extends it for AI-based diagnostic tests.
For systematic reviews of diagnostic accuracy studies, use PRISMA 2020 with the DTA extension. For interpreting sensitivity and specificity from your own data, see the diagnostic accuracy calculator or the ROC / AUC calculator.
Need help with your review or manuscript? Statistical analysis from $350 · Manuscript writing from $800 · Publication support from $150
Get a quote →Worked Examples
A diagnostic study enrolled 600 patients with chronic liver disease referred for staging. 100 were excluded (contraindications to biopsy: 60, withdrew consent: 40). 500 received the index test (FIB-4 score). 30 did not receive the reference standard (liver biopsy) because of coagulopathy or patient preference. 470 received both tests. 20 were excluded from analysis due to inadequate biopsy sample. 450 were included in the 2×2 table for sensitivity/specificity calculation. Enter these numbers — the diagram auto-calculates at each stage.
A prospective diagnostic study recruited 400 patients presenting to primary care with cough and fever. 80 were ineligible (age under 18, prior antibiotic use). 320 received POC CRP (index test); 10 had failed capillary samples. Of 310 who received the index test, all received the reference standard (chest X-ray + microbiological culture). 15 had technically inadequate cultures; 295 were analysed. Enter 400 enrolled, 80 excluded, 320 index test, 10 failed, 310 reference standard, 0 not received, 295 analysed — the diagram populates across three stages.
Assumptions and Requirements
- Index test and reference standard are both required in STARD. The flow must show separately how many participants received the index test and how many received the reference standard. Patients who received only one are at risk of verification bias — document them explicitly.
- Reason for not receiving reference standard must be stated. STARD 2015 item 10 specifically requires the reason for non-receipt of the reference standard (e.g. refused, too ill, contra-indicated). Use the click-to-edit feature to add this detail to the testing box.
- Analysis exclusions must be justified. Participants who received both tests but were excluded from analysis (e.g. inadequate specimen) must appear in the final stage with a stated reason.
Common Mistakes
- Ignoring differential verification. If only test-positive patients received the reference standard, this is differential verification bias — the most serious methodological threat in diagnostic studies. The STARD flow diagram makes this visible; your Discussion must address it.
- Conflating test failure with exclusion from analysis. A failed or indeterminate index test result is not the same as being excluded from the analysis. Indeterminate results should be reported and their handling stated in Methods.
- Using the incorrect reference standard. STARD requires the reference standard to be described precisely. If you used a composite reference standard (e.g. imaging plus clinical follow-up), state this in the Testing box — click to edit it.
- Using STARD 2003 instead of 2015. The 2003 version is no longer current. STARD 2015 has a 30-item checklist and a revised flow diagram that separates index test and reference standard receipt more explicitly.
Frequently Asked Questions
Related Free Tools
References
- Bossuyt PM, Reitsma JB, Bruns DE, et al. STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies. BMJ. 2015;351:h5527. PMID 26511519.
- Cohen JF, Korevaar DA, Altman DG, et al. STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration. BMJ Open. 2016;6:e012799. PMID 28137831.
- Sounderajah V, Guni A, Liu X, et al. The STARD-AI reporting guideline for diagnostic accuracy studies using artificial intelligence. Nat Med. 2025;31(10):3283-3289. PMID 40954311.
- Whiting PF, Rutjes AW, Westwood ME, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155:529–536.